Introduction of customized explosion-proof control cabinet: maintenance knowledge of control cabinet!

Introduction of customized explosion-proof control cabinet: maintenance knowledge of control cabinet!

  • Categories:News & Events
  • Author:
  • Origin:
  • Time of issue:2021-08-26
  • Views:0

(Summary description)The control cabinet is to assemble the switchgear, measuring instruments, protective appliances and auxiliary equipment in a closed or semi-enclosed metal cabinet or on the screen according to the electrical wiring requirements. The layout should meet the requirements of the normal operation of the power system, which is convenient for maintenance and does not endanger people. And the safety of surrounding equipment.

Introduction of customized explosion-proof control cabinet: maintenance knowledge of control cabinet!

(Summary description)The control cabinet is to assemble the switchgear, measuring instruments, protective appliances and auxiliary equipment in a closed or semi-enclosed metal cabinet or on the screen according to the electrical wiring requirements. The layout should meet the requirements of the normal operation of the power system, which is convenient for maintenance and does not endanger people. And the safety of surrounding equipment.

  • Categories:News & Events
  • Author:
  • Origin:
  • Time of issue:2021-08-26
  • Views:0
Information

The control cabinet is to assemble the switchgear, measuring instruments, protective appliances and auxiliary equipment in a closed or semi-enclosed metal cabinet or on the screen according to the electrical wiring requirements. The layout should meet the requirements of the normal operation of the power system, which is convenient for maintenance and does not endanger people. And the safety of surrounding equipment. During normal operation, the circuit can be switched on or off by means of manual or automatic switches. So how much do you know about its maintenance knowledge? Let's follow the editor of the customized explosion-proof control cabinet to have a simple understanding!
1. Disconnect the power supply, check whether the frame of the control cabinet has a reliable grounding, and make the grounding resistance not greater than 4Ω.
2. There are voltages of different natures on the control cabinet (DC 110V; AC single-phase 220V; three-phase AC). It is necessary to distinguish the circuit during maintenance to prevent short circuit accidents.
3. All electrical switches on the control cabinet should act flexibly and reliably without significant noise. There should be no loosening of the connecting wire knots and terminals, and there should be no breakage of the steel wire at the connecting wire knots of the movable contact.
4. Use a soft brush or air blower to remove the dust on the screen board plug-in unit and all the electromagnetic switch parts, and check the state of the electrical switch contacts in the control cabinet, the contact condition, the insulation of the coil surface and the operation of the mechanical parts are reliable.
5. When replacing the fuse, make the fusing current match the current of the loop.
The above is the editor of the customized explosion-proof control cabinet: about the maintenance and maintenance of the control cabinet.

Keyword:

Scan the QR code to read on your phone

More News

Quality

Quality explosion proof stacker truck For sale introduces the operating procedures of stacker trucks

Before use, carefully check the hydraulic pipeline of the vehicle for oil leakage, whether the supporting wheels can work normally, and whether there is any blocking phenomenon. It is strictly forbidden to use the faulty vehicle. Open the electric door lock and check the universal meter on the dashboard to observe whether the battery is charged. If a bar on the left end is lit, it indicates that the battery is out of power. Check whether the vehicle's lifting, lowering and other actions are normal.
2021-10-15
quality

quality explosion proof stacker truck For sale introduces the operation precautions of stacker truck

When the ambient temperature is +40℃, the relative humidity does not exceed 50%. At lower temperatures, a higher relative humidity is allowed;
2021-10-14
A

A brief introduction to the relevant knowledge of explosion-proof light from China manufacturer

When replacing the bulb (tube), the explosion-proof light from China manufacturer's explosion-proof joint surface should be properly protected and not damaged; the cleaned explosion-proof surface should be coated with phosphating paste or 204-1 anti-rust oil, and brushing is strictly prohibited Other paints;
2021-10-01
The

The principle of explosion-proof light from China manufacturer

There are two reasons for electrical equipment to ignite flammable gas mixtures: one is sparks and arcs generated by electrical equipment, and the other is heating of electrical equipment surfaces (that is, surfaces in contact with flammable gas mixtures).
2021-09-30
Previous page
1
2
8

页脚联系我们

Time of issue:2020-12-07 18:30:37

Suzhou Hazardtex Mechanical Equipment Co., LTD

Address:7-B1 Plant No.59 Weixin Road, Suzhou Industrial Park, Suzhou, Jiangsu Province, P. R. China

Mr. Li: +8613771823229

Miss Huang: +86 512 69570129

Email:haojun.li@hazardtex.com

http://www.hazardtex.com

 

Service hot line:

Mr. Wu: +8613701544403

Alibaba

Copyright:Suzhou Hazardtex Mechanical Equipment Co., LTD   苏ICP备16005497号-1